LL80
High-Capacity Centrifuge
Request a Quote
Features
- CE and CFDA certified for high reliability
- Up to 96 blood tubes can be processed in one run
- Composite shock absorber for more stable operation
- High centrifugal performance up to 5500 rpm (3910 × g)
- Supports tube capacities from 0.2 ml to 500 ml
- Compatible with swing-out rotors, fixed-angle rotors, and microplate rotors
- Biosafety design to help avoid aerosol contamination
Specification
| Parameter | Details | |||
| Speed Range | 300–5500 rpm, step: 1 rpm | |||
| Speed Accuracy | ±20 rpm | |||
| RCF Range | 20–3910 × g, step: 1 × g | |||
| Rotor | Model | No | Parameters | Biosafety |
| S4-500A | 1# | 500 ml × 4, 3500 rpm (2570 × g) | Yes | |
| S4-500B | 2# | 400 ml × 4, 4000 rpm (3200 × g) | No | |
| S2-MP96 | 3# | 3 microplates × 2, 4000 rpm (2218 × g) | No | |
| A8-50 | 4# | 15 ml × 16 or 50 ml × 8, 5000 rpm (3910 × g) | No | |
| A30-15 | 5# | 15 ml × 30, 5000 rpm (3910 × g) | No | |
| FS8-50 | 6# | 50 ml × 8, 5500 rpm (3652 × g) | Yes | |
| Timer | 10 sec–99 min, continuous | |||
| Program Number | 9 | |||
| Deceleration Curve | ↑9 ↓10; ↓0: free stop | |||
| MSM Mode | Gentle acceleration and slow deceleration | |||
| Safety Devices | Door interlock, overspeed detector, overtemperature protection, imbalance detection | |||
| Dimensions (cm) & Weight | (W) 47 × (D) 57.7 × (H) 33.5, 50 kg | |||
| Power Requirements | AC 220V, 50Hz, 10A | |||
| Additional Features | Speed/RCF switch, pulse operation, process display, rotor identification | |||
Rotor Specification
S4-500A Rotor
- 3500 rpm / 2570 × g
- 4 × 500 ml (conical)
- 4 × 250 ml (conical)
- 20 × 50 ml (conical)
- 48 × 15 ml (conical)
- 72 × 10 ml (blood tubes)
- 96 × 3–7 ml (blood tubes)
A30-15 Rotor
- 5000 rpm / 3910 × g
- 30 × 15 ml
- 30 × 10 ml
- 30 × 3–7 ml blood tubes (with A15P7 adapter)
S4-500B Rotor
- 4000 rpm / 3200 × g
- 16 × 50 ml (conical)
- 36 × 15 ml (conical)
- 60 × 10 ml (blood tubes)
- 72 × 3–7 ml (blood tubes)
FS8-50 Rotor
- 5500 rpm / 3652 × g
- 8 × 50 ml
- 8 × 15 ml (with A50P15 adapter)
S2-MP96 Rotor
- 4000 rpm / 2218 × g
- 2 × 3 microplates
A8-50 Rotor
- 5000 rpm / 3910 × g
- 8 × 50 ml
- 16 × 15 ml
A15P7 Adapter
A50P15 Adapter
S4-500A Rotor Configuration
| S4-500A Rotor | | ![]() | ![]() | | | | |
| Description | Vacuum Blood Tube | 10 ml Tube | 15 ml Tube | 50 ml Culture Tube | 500 ml Conical | 250 ml Conical | |
| Ø × L (mm) | 13 × 75 | 13 × 106 | 15 × 106 | 17 × 120 | 29 × 109 | 95 × 147 | 60 × 165 |
| Tube | | | | | ![]() | ![]() | ![]() |
| Number / Bucket | 24 | 24 | 18 | 14 | 5 | 1 | 1 |
| Number / Rotor | 96 | 96 | 72 | 56 | 20 | 4 | 4 |
| Adapter | A500P5Y | A500P10Y | A500P15Y | A500P50Y | A500P250Y | A500P500Y | |
| Bucket Lid | yes | no | no | ||||
High-Quality Rotor
- Precision-machined rotor
- Not cast
- High quality construction
- Designed to help prevent aerosol contamination
Warranty
- This centrifuge is covered by a 2-year warranty